Feasibility of a Fully Implanted, Nickel Sized and Shaped Tibial Nerve Stimulator for the Treatment of Overactive Bladder Syndrome with Urgency Urinary Incontinence
Rattachement africain : us, nz. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: We performed a clinical feasibility trial to evaluate the safety and efficacy of a fully implanted, primary battery powered, nickel sized and shaped neuromodulation device called the eCoin® for tibial nerve stimulation to treat refractory urgency urinary incontinence. MATERIALS AND METHODS: This prospective, single arm, open label study included 46 participants with refractory urgency urinary incontinence. It was performed at multiple sites in the United States and New Zealand. The device was implanted in the lower leg over the tibial nerve and activated after 4 weeks. Bladder diary data and validated quality of life instruments were collected 3 and 6 months after activation and compared to baseline values. RESULTS: The mean ± SD age of participants was 63.4 ± 11.5 years and 45 (98%) were female. Episodes of urgency urinary incontinence were reduced a relative median of 71% after 3 months of treatment (4.2 vs 1.7 daily episodes at 3 months, p = 0.001). A 50% or greater decrease in reported episodes of urgency urinary incontinence was observed in 32 of 46 participants (69.6%) at 3 months with more than 20% dry at 3 and 6 months. I-QOL (Incontinence Quality of Life) scores improved an average of 25.9 points and 33 of 46 patients (72%) indicated improvement in symptoms. A single serious adverse event secondary to wound care resolved with intravenous antibiotics. CONCLUSIONS: The implantable neuromodulation device was a safe and effective treatment of urgency urinary incontinence associated with overactive bladder syndrome with a significant reduction or resolution of symptoms and no significant safety concerns.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Feasibility of a Fully Implanted, Nickel Sized and Shaped Tibial Nerve Stimulator for the Treatment of Overactive Bladder Syndrome with Urgency Urinary Incontinence
- Date Crossref
- 01/05/2019
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.