Aller au contenu principal
Accès ouvert déclaré 2018 article

Summarizing the 4D image stack of ultrafast dynamic contrast enhancement MRI of breast cancer in 3D using color intensity projections

9Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Each ultrafast dynamic contrast-enhanced (DCE) MRI sequence for breast cancer generates thousands of images in a 4D stack that need to be reviewed by a radiologist. PURPOSE: To assess whether color intensity projections (CIP) effectively summarizes-using only the time of arrival (ToA) and amount of signal enhancement (AoE) of the contrast agent-the thousands of ultrafast images. STUDY TYPE: Retrospective cohort clinical trial. SUBJECTS: The study included 89 patients who had been scanned with an MRI beast protocol, of which 26 had breast cancer and 63 did not. FIELD STRENGTH/SEQUENCE: The 115-second ultrafast DCE sequence at 3T acquired 19 consecutive frames every 4.26 seconds with 152 slices per frame, yielding a 4D stack with 2888 2D images for each of water and fat. ASSESSMENT: For each slice of the water 4D stack a single CIP image was generated that encoded the ToA in the hue (red, orange, yellow, green, cyan, blue) and AoE in the brightness. Each of three experienced radiologists assigned a Breast Imaging and Reporting Data System (BI-RADS) score for each patient, first using only the CIP images, and subsequently using both CIP and the full 4D stack. STATISTICAL TESTS: The one-sided Fisher's exact test was used to determine statistical significance of both the sensitivity and specificity between the CIP alone and the CIP plus 4D stack. RESULTS: All malignancies were detected using only CIP by at least one of the radiologists. The CIP and CIP+4D sensitivities for reader 1 were 96% and 96% (P = 0.57), specificities were 59% and 65% (P = 0.29). For reader 2, the values were 96% and 100% (P = 0.51) with 62% and 71% (P = 0.17). For reader 3 the values were 92% and 96% (P = 0.50) with 51% and 62% (P = 0.07). DATA CONCLUSION: With a 95% sensitivity, CIP provides an effective summary of ultrafast DCE images of breast cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1391-1399.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Summarizing the 4D image stack of ultrafast dynamic contrast enhancement MRI of breast cancer in 3D using color intensity projections
Date Crossref
14/10/2018
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

MRI in cancer diagnosisBreast Cancer Treatment StudiesLanthanide and Transition Metal Complexes

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.