Purpose: The study was aimed to compare hybrid arc and volumetric-modulated arc therapy treatment plans for fractionated stereotactic radiotherapy of brain tumors. Methods: Treatment plans of 22 patients were studied. Hybrid arc and volumetric-modulated arc therapy plans were generated using Brainlab iPlanDose and Varian Eclipse treatment planning systems, respectively, with 6 MV photon beams on a Varian TrueBeam STx linear accelerator (Palo Alto, CA). Prescription dose was 54 Gy. The fractionation was 1.8 Gy per fraction and 30 fractions in total, or 2 Gy per fraction and 27 fractions in total. Planning target volume ranged from 2.4 to 28.6 cm 3 . Dose conformity index, gradient index, homogeneity index, and maximum doses in organs at risk were compared. Wilcoxon signed rank test was used to determine statistical significance in paired comparison. Results: Conformity indexes of hybrid arc and volumetric-modulated arc therapy plans are 1.10 ± 0.10 and 1.14 ± 0.07, respectively ( P = .4); gradient indexes are 5.02 ± 1.20 and 5.64 ± 1.28, respectively ( P = .0001); homogeneity indexes are 1.02 ± 0.01 and 1.05 ± 0.01, respectively ( P = .0001); brainstem maximum doses are 53.87 ± 1.63 Gy and 54.06 ± 3.17 Gy, respectively ( P = .1); and optic chiasm maximum doses are 53.86 ± 1.28 Gy and 53.95 ± 1.81, respectively ( P = .4). The monitor unit efficiencies of hybrid arc and volumetric-modulated arc therapy plans are 2.57 ± 0.25 MU/cGy and 2.68 ± 0.24 MU/cGy, respectively ( P = .2). The differences of conformity index, gradient index, and homogeneity index between hybrid arc and volumetric-modulated arc therapy plans are small: 0.08 ± 0.05, 0.65 ± 0.46, and 0.02 ± 0.01, respectively. The maximum doses in organs at risks are similar between hybrid arc and volumetric-modulated arc therapy plans. Hybrid arc and volumetric-modulated arc therapy plans, which have similar monitor unit efficiencies, present similar dosimetric results in the fractionated intracranial radiotherapy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of Hybrid Arc and Volumetric-Modulated Arc Therapy Treatment Plans for Fractionated Stereotactic Intracranial Radiotherapy
Date Crossref
01/01/2018
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Radiotherapy TechniquesBrain Metastases and TreatmentGlioma Diagnosis and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.