Aller au contenu principal
Accès ouvert déclaré 2018 article

A collaborative study by the Working Group on Hemostasis and Thrombosis of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC) on the interference of haemolysis on five routine blood coagulation tests by evaluation of 269 paired haemolysed/non-haemolysed samples

16Citations signalées, ce qui n’est pas une note de qualité
23Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : it, cz, us, fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: new, non-haemolysed (NH) specimens, collected within 4hrs. As new coagulometers can identify interfering substances, visual assessment of haemolysis was also compared with instrumental haemolysis index and stratified in subclasses. MATERIALS AND METHODS: Two hundred and sixty nine paired samples were collected and analysed using ACL TOP750-CTS (Instrumentation Laboratory, Bedford, USA), for prothrombin time (PT), activated partial thromboplastin time (aPTT), D-Dimer (DD), fibrinogen (Fib) and antithrombin (AT). Bias between H and NH was calculated and compared with the respective critical difference (CD). RESULTS: Mean bias was - 0.1 s for PT (P = 0.057), - 1.1 s for aPTT (P < 0.001), 1025 ng/mL for DD (P < 0.001), - 0.04 g/L for Fib (P = 0.258) and 1.4% for AT (P = 0.013). Bias exceeding the CD varied according to the method, with larger differences for aPTT (36.1%) and DD (17.1%) and < 8% for PT, Fib and AT. No correlation emerged between free haemoglobin values and difference in haemostasis tests in H and NH samples for any tests. Moderate/severe haemolysis involved > 95% of samples. The agreement between visual assessment and instrumental evaluation of haemolysis was 0.62. CONCLUSION: Spurious haemolysis deeply influences aPTT and DD, and to a lesser extent AT and Fib. Prothrombin time seems only slightly influenced, suggesting that PT can be accepted also in haemolysed samples. Although a good inter-observer correlation of haemolysis evaluation was found, the instrumental assessment of haemolysis seems recommendable.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A collaborative study by the Working Group on Hemostasis and Thrombosis of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC) on the interference of haemolysis on five routine blood coagulation tests by evaluation of 269 paired haemolysed/non-haemolysed samples
Date Crossref
15/10/2018
Éditeur
Croatian Society for Medical Biochemistry and Laboratory Medicine
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Clinical Laboratory Practices and Quality ControlBlood Coagulation and Thrombosis MechanismsBlood properties and coagulation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.