3071Assessment of long-term structural deterioration of transcatheter aortic bioprosthetic valves using standardized new european definitions, a multicenter study
Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: In the context of extension of transcatheter aortic valve implantation (TAVI) indications to lower-risk patients, long-term durability of transcatheter aortic bioprosthetic valves (TABV) is a crucial issue. There is a paucity of data, especially beyond 5 years of follow-up. Recently, new definitions have been proposed to assess structural valve deterioration (SVD) and bioprosthetic valve failure (BVF). Purpose: We aim to assess long-term SVD and BVF of TABV using standardized new definitions. Methods: All TAVI patients implanted between 2002 and 2011 in 5 centers were included (balloon-expandable TABV in 83.6%, and 65.4% via transfemoral approach). One month and last available echocardiographic follow-up were used to assess SVD and BVF according to the new European criteria. SVD was assessed in patients with an echocardiographic control performed less than one year before last follow-up. Competing-risk analysis was used to assess SVD and BVF incidence. Results: Over the study period, 1,403 patients were included. Mean age and logistic EuroSCORE were 82.6±7.5 years and 21.3±7.5%, respectively. Mean duration follow-up was 3.6±2.1 years with a maximum of 10.2 years, 30.1% of patients were followed beyond 5 years. Thirty-day mortality was 9.9%. Survival rates were 83.5% (95% CI: 81.4–85.5), 18.6% (95% CI: 15.3–21.8) and 8.0% (95% CI: 1.9–14.2) at 1, 7 and 10 years, respectively. BVF occurred in 18 patients of whom 5 required reoperation with a mean delay of 5.5±1.3 years. Incidence of BVF was 2.2% (95% CI: 1.2–3.7) and 3.4 (95% CI: 1.7–5.9) at 7 and 10 years, respectively. Among 589 patients eligible for the SVD analysis, 41 had moderate SVD and 15 had severe SVD. Incidence of moderate SVD was 9.2% (95% CI: 6.5–12.6) and 16.6% (95% CI: 9.1–26.0) at 7 and 10 years, respectively. Incidence of severe SVD was 4.4% (95% CI: 2.2–7.9) and 8.0% (95% CI: 3.3–15.2) at 7 and 10 years, respectively.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 3071Assessment of long-term structural deterioration of transcatheter aortic bioprosthetic valves using standardized new european definitions, a multicenter study
- Date Crossref
- 01/08/2018
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.