Safety and Efficacy of Diode Laser Transscleral Cyclophotocoagulation in Eyes With Good Visual Acuity
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND/AIMS: The main aim of this study was to evaluate the safety and efficacy of diode laser transscleral cyclophotocoagulation (TSCPC) in eyes with good visual acuity. PATIENTS AND METHODS: A retrospective chart review identified patients who underwent TSCPC for uncontrolled intraocular pressure (IOP) from 2014 to 2016. Enrollment criteria included pretreatment best-corrected visual acuity (BCVA) of 20 of 40 or better, and a minimum of 6 months of postoperative follow-up. RESULTS: Thirty-three eyes of 33 patients(mean age, 72.1±16.0 y) were enrolled (mean follow-up 12.6±6.1 mo). The mean (SD) IOP was reduced 48.3% from 27.1 mm Hg (7.8) at baseline to 13.1 mm Hg (4.2) at last follow-up. Reduction of ≥1 glaucoma medications was achieved in 17 eyes (51.5%) at last follow-up. The cumulative probability of complete success (BCVA loss <2 Snelling lines, 20% reduction IOP, no reoperation for glaucoma, no IOP<5 mm Hg) was 78.8% and 50% at months 6 and 12, respectively. The cumulative probability of qualified success (BCVA≥2 lines with ≥20% reduction IOP, no reoperation for glaucoma, no IOP<5 mm Hg) was 90.1% and 81.3% at month 6 and 1 year, respectively. Significant vision loss, defined as BCVA≥2 lines, occurred in 33% of patients. The most common complications were postoperative iritic (56.3%) and cystoid macular edema (12.5%). CONCLUSIONS: TSCPC demonstrates a strong reduction in IOP and glaucoma medication use. However, with significant vision loss in 33% of patients, future prospective studies with a comparison group receiving traditional glaucoma surgery are needed to determine comparative safety and efficacy.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Safety and Efficacy of Diode Laser Transscleral Cyclophotocoagulation in Eyes With Good Visual Acuity
- Date Crossref
- 01/10/2018
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Miami Department of Ophthalmology pays non établi dans la noticeUniversité ou école supérieure
Department of Ophthalmology — University of Miami.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.