Knee dGEMRIC at 7 T: comparison against 1.5 T and evaluation of T1-mapping methods
Rattachement africain : se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
dGEMRIC (delayed Gadolinium Enhanced Magnetic Resonance Image of Cartilage) is a well-established technique for cartilage quality assessment in osteoarthritis at clinical field strengths. The method is robust, but requires injection of contrast agent and a cumbersome examination procedure. New non-contrast-agent-based techniques for cartilage quality assessment are currently being developed at 7 T. However, dGEMRIC remains an important reference technique during this development. The aim of this work was to compare T 1 mapping for dGEMRIC at 7 T and 1.5 T, and to evaluate three T 1 -mapping methods at 7 T. The knee of 10 healthy volunteers and 9 patients with early signs of cartilage degradation were examined at 1.5 T and 7 T after a single (one) contrast agent injection (Gd-(DTPA) 2− ). Inversion recovery (IR) sequences were acquired at both field strengths, and at 7 T variable flip angle (VFA) and Look-Locker (LL) sequences were additionally acquired. T 1 maps were calculated and average T 1 values were estimated within superficial and deep regions-of-interest (ROIs) in the lateral and medial condyles, respectively. T 1 values were 1.8 (1.4–2.3) times longer at 7 T. A strong correlation was detected between 1.5 T and 7 T T 1 values ( r = 0.80). For IR, an additional inversion time was required to avoid underestimation (bias±limits of agreement − 127 ± 234 ms) due to the longer T 1 values at 7 T. Out of the two 3D sequences tested, LL resulted in more accurate and precise T 1 estimation compared to VFA (average bias±limits of agreement LL: 12 ± 202 ms compared to VFA: 25 ± 622 ms). For both, B 1 correction improved agreement to IR. With an adapted sampling scheme, dGEMRIC T 1 mapping is feasible at 7 T and correlates well to 1.5 T. If 3D is to be used for T 1 mapping of the knee at 7 T, LL is preferred and VFA is not recommended. For VFA and LL, B 1 correction is necessary for accurate T 1 estimation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Knee dGEMRIC at 7 T: comparison against 1.5 T and evaluation of T1-mapping methods
- Date Crossref
- 16/05/2018
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Lund University Department of Translational Medicine pays non établi dans la noticeUniversité ou école supérieure
-
Skåne University Hospital Department of Oncology and Radiation Physics pays non établi dans la noticeÉtablissement de santé
Department of Translational Medicine — Lund University et Department of Oncology and Radiation Physics — Skåne University Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.