123I-MIBG myocardial scintigraphy for the diagnosis of DLB: a multicentre 3-year follow-up study
Rattachement africain : jp, ca, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background and purpose We previously reported the usefulness of iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy for differentiation of dementia with Lewy bodies (DLB) from Alzheimer’s disease (AD) in a cross-sectional multicentre study. The aim of this study was, by using reassessed diagnosis after 3-year follow-up, to evaluate the diagnostic accuracy of 123I-MIBG scintigraphy in differentiation of probable DLB from probable AD. Methods We undertook 3-year follow-up of 133 patients with probable or possible DLB or probable AD who had undergone 123I-MIBG myocardial scintigraphy at baseline. An independent consensus panel made final diagnosis at 3-year follow-up. Based on the final diagnosis, we re-evaluated the diagnostic accuracy of 123I-MIBG scintigraphy performed at baseline. Results Sixty-five patients completed 3-year follow-up assessment. The final diagnoses were probable DLB (n=30), possible DLB (n=3) and probably AD (n=31), and depression (n=1). With a receiver operating characteristic curve analysis of heart-to-mediastinum (H/M) ratios for differentiating probable DLB from probable AD, the sensitivity/specificity were 0.77/0.94 for early images using 2.51 as the threshold of early H/M ratio, and 0.77/0.97 for delayed images using 2.20 as the threshold of delayed H/M ratio. Five of six patients who were diagnosed with possible DLB at baseline and with probable DLB at follow-up had low H/M ratio at baseline. Conclusions Our follow-up study confirmed high correlation between abnormal cardiac sympathetic activity evaluated with 123I-MIBG myocardial scintigraphy at baseline and the clinical diagnosis of probable DLB at 3-year follow-up. Its diagnostic usefulness in early stage of DLB was suggested. Trial registration number UMIN00003419.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- <sup>123</sup>I-MIBG myocardial scintigraphy for the diagnosis of DLB: a multicentre 3-year follow-up study
- Date Crossref
- 31/05/2018
- Éditeur
- BMJ
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.