Aller au contenu principal
2017 article

Evaluation of a lateral flow–based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions

1Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Life-threatening situations requiring blood transfusion under extreme conditions or in remote and austere locations, such as the battlefield or in traffic accidents, would benefit from reliable blood typing practices that are easily understood by a nonscientist or nonlaboratory technician and provide quick results. STUDY DESIGN AND METHODS: A simplified protocol was developed for the lateral flow-based device MDmulticard ABO-D-Rh subgroups-K. Its performance was compared to a reference method (PK7300, Beckman Coulter) in native blood samples from donors. The method was tested on blood samples stressed in vitro as a model of hemorrhage cases (through hemodilution using physiologic serum) and dehydration (through hemoconcentration by removing an aliquot of plasma after centrifugation), respectively. RESULTS: A total of 146 tests were performed on 52 samples; 126 in the hemodilution group (42 for each native, diluted 1/2, and diluted 1/4 samples) and 20 in the hemoconcentration group (10 for each native and 10% concentrated samples). Hematocrit in the tested samples ranged from 9.8% to 57.6% while hemoglobin levels ranged from 3.2 to 20.1 g/dL. The phenotype profile detected with the MDmulticard using the simplified protocol resulted in 22 A, seven B, 20 O, and three AB, of which nine were D- and five were Kell positive. No discrepancies were found with respect to the results obtained with the reference method. CONCLUSION: The simplified protocol for MDmulticard use could be considered a reliable method for blood typing in extreme environment or emergency situations, worsened by red blood cell dilution or concentration.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluation of a lateral flow–based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions
Date Crossref
29/11/2017
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Blood groups and transfusionBlood transfusion and managementClinical Laboratory Practices and Quality Control

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.