Site contributions for radiated emission measurement uncertainties above 1 GHz
Le résumé fourni par la source
Guidance on accounting for site imperfections in the uncertainty evaluation of emissions measurement result is provided by CISPR 16-4-2. Site Voltage Standing Wave Ratio (SVSWR) results from the chamber are used as the basis for estimating the uncertainty contributions due to the site. In this paper, we investigate two aspects of the uncertainty evaluation, and provide a method to estimate the uncertainties based on measured SVSWR data. Firstly, considering that the SVSWR results are under-sampled and under-reported using the current method, is it valid to assume 6 dB as the maximum SVSWR of the chamber? Secondly, SVSWR measurements are only performed at the front, left, right, and center (optionally) of the quiet zone (QZ). We study if those locations are adequate representations of the entire QZ performance.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Site contributions for radiated emission measurement uncertainties above 1 GHz
- Date Crossref
- 01/08/2017
- Éditeur
- IEEE
- Type
- proceedings-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.