Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy
Rattachement africain : gb, au. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
There is increasing interest in MR-only radiotherapy planning since it provides superb soft-tissue contrast without the registration uncertainties inherent in a CT-MR registration. However, MR images cannot readily provide the electron density information necessary for radiotherapy dose calculation. An algorithm which generates synthetic CTs for dose calculations from MR images of the prostate using an atlas of 3 T MR images has been previously reported by two of the authors. This paper aimed to evaluate this algorithm using MR data acquired at a different field strength and a different centre to the algorithm atlas. Twenty-one prostate patients received planning 1.5 T MR and CT scans with routine immobilisation devices on a flat-top couch set-up using external lasers. The MR receive coils were supported by a coil bridge. Synthetic CTs were generated from the planning MR images with ([Formula: see text]) and without (sCT) a one voxel body contour expansion included in the algorithm. This was to test whether this expansion was required for 1.5 T images. Both synthetic CTs were rigidly registered to the planning CT (pCT). A 6 MV volumetric modulated arc therapy plan was created on the pCT and recalculated on the sCT and [Formula: see text]. The synthetic CTs' dose distributions were compared to the dose distribution calculated on the pCT. The percentage dose difference at isocentre without the body contour expansion (sCT-pCT) was [Formula: see text] and with ([Formula: see text]-pCT) was [Formula: see text] (mean ± one standard deviation). The [Formula: see text] result was within one standard deviation of zero and agreed with the result reported previously using 3 T MR data. The sCT dose difference only agreed within two standard deviations. The mean ± one standard deviation gamma pass rate was [Formula: see text] for the sCT and [Formula: see text] for the [Formula: see text] (with [Formula: see text] global dose difference and [Formula: see text] distance to agreement gamma criteria). The one voxel body contour expansion improves the synthetic CT accuracy for MR images acquired at 1.5 T but requires the MR voxel size to be similar to the atlas MR voxel size. This study suggests that the atlas-based algorithm can be generalised to MR data acquired using a different field strength at a different centre.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy
- Date Crossref
- 21/11/2017
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Newcastle upon Tyne Hospital Northern Centre for Cancer Care pays non établi dans la noticeÉtablissement de santé
-
Commonwealth Scientific and Industrial Research Organisation pays non établi dans la noticeOrganisme public
-
Australian e-Health Research Centre pays non établi dans la noticeStructure de recherche
-
University of Leeds Leeds Institute of Cancer and Pathology pays non établi dans la noticeUniversité ou école supérieure
-
Leeds Teaching Hospitals NHS Trust Leeds Cancer Centre pays non établi dans la noticeÉtablissement de santé
-
Calvary Mater Newcastle Hospital pays non établi dans la noticeÉtablissement de santé
-
University of Newcastle Australia pays non établi dans la noticeUniversité ou école supérieure
Northern Centre for Cancer Care — Newcastle upon Tyne Hospital, Commonwealth Scientific and Industrial Research Organisation et Australian e-Health Research Centre, avec 4 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.