Aller au contenu principal
Accès ouvert déclaré 2017 article

35 Uk multi-centre registry of transvenous lead extraction: clinical outcome using different techniques

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : sk, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction With increasing numbers and complexity of implantable devices, the need for lead extraction is also increasing. There is little UK data available on clinical outcomes. We compiled a multi-centre registry of patients undergoing lead extraction to investigate predictors of success and complications. Methods Data on all cases at three UK tertiary centres (St. Barts and The Heart Hospital London and Papworth Hospital Cambridge) were collected over 18 months. Cases where leads were >1 year in age or where specialist extraction equipment was used were included (cases=137, leads=268). Results 69% of patients were male, age 66±16 years (mean±SD). Devices extracted were single chamber PPMs (5%), dual chamber PPMs (42%), CRTPs (6%), single chamber ICDs (6%), dual chamber ICDs (17%) and CRTDs (24%). 76% of ICD leads were dual coil. Number of leads extracted per patient was 2.0±1.0 and time from implantation was 8.3±11.1 years. Leads were extracted using simple traction (39%), traction with locking stylets alone (8%) or dilator sheaths (5%), bidirectional cutting sheaths (38%) or laser (10%). Only 2% of cases required additional femoral access. Specialist equipment was preferentially used for older leads (10.4±13.1 vs 5.2±5.8 years, p<0.001) and for ICD leads (84% vs 53%, p<0.001). The rate of major procedural adverse events (AE) leading to death or emergent surgery was 2.2%, major AEs unrelated to the procedure was 5.8% and minor AEs was 8.7%. Predictors of AEs include patient age (77±28 vs 66±15 years, p=0.05), the age but not type or number of lead (14.8±24.5 vs 7.2±6.0 years, p=0.01), systemic infectiona(31 vs 8%, p<0.001), increased creatinine level (142±111 vs 108±23 µmol/L, p=0.011), decreased haemoglobin level (109±23 vs 123±24 g/L, p=0.001) and use of assisted traction or laser over simple traction or mechanical cutting sheathsb (p=0.001) – see Table. Complete extraction was achieved in 95.5% of leads, with only 2.2% with >4 cm of lead remaining in situ. Predictors of procedural failure include age but not type or number of leads (11.1±8.6 vs 8.3±11.3 years, p=0.05), systemic infectionc(24 vs 3%, p<0.001) and increased creatinine (162±126 vs 108±66 µmol/L, p=0.012). Laser extraction resulted in 100% success in removing leads. Gender, procedure duration, fluoroscopy time and dose, use of general anaesthesia or temporary pacing was independent of extraction technique and outcome. Discussion This is the first UK prospective multi-centre study of lead extraction data comparing extraction techniques. Overall there is a low major complication and high success rate with the use of either simple traction or specialist equipment. From our findings, high risk cases can be identified pre-procedure to allow adequate case planning. Laser extraction is clinically effective but is associated with a higher complication rates compared with mechanical cutting sheaths. Abstract 35 Table 1 Uncomplicated extraction (%) Major AE due to procedure (%) Major AE not due to procedure (%) Minor AE (%) Procedural failure (%) >4 cm lead remaining (%) Reason extracted Pocket infection 59 (87) 0 (0) 0 (0) 9 (13) 2 (3) 2 (3) Box erosion 43 (86) 3 (6) 0 (0) 4 (8) 1 (2) 0 (0) Systemic infection 36 (69) a 0 (0) 6 (12) a

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
35 Uk multi-centre registry of transvenous lead extraction: clinical outcome using different techniques
Date Crossref
01/06/2017
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Art Research Centre of the Slovak Academy of Sciences pays non établi dans la notice
    Structure de recherche
  • Papworth Hospital NHS Foundation Trust pays non établi dans la notice
    Établissement de santé
  • Barts Heart Centre pays non établi dans la notice
    Institution

Art Research Centre of the Slovak Academy of Sciences, Papworth Hospital NHS Foundation Trust et Barts Heart Centre.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.