Response of Tunnel in Saturated Soil to an Underwater Explosion
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
A combination of physical model tests and numerical analyses was utilized to study the effects of an explosion on an underground tunnel, located below a body of water. Strains induced on the tunnel because of the explosion were measured in centrifuge model tests conducted at 70 g. Three-dimensional numerical analyses using an explicit dynamic hydrocode were also conducted. The results of the numerical analyses showed favorable comparison with those from centrifuge model tests. The results indicated that, for the same mass of explosives, the damage to the tunnel increased with increasing height of water up to a certain maximum height. When the water level was increased beyond this height, the magnitude of damage remained relatively unchanged and did not appear to increase further.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Response of Tunnel in Saturated Soil to an Underwater Explosion
- Date Crossref
- 06/07/2017
- Éditeur
- American Society of Civil Engineers
- Type
- proceedings-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.