Aller au contenu principal
Accès ouvert déclaré 2017 article

Salivary gland ultrasound abnormalities in primary Sjögren’s syndrome: consensual US-SG core items definition and reliability

100Citations signalées, ce qui n’est pas une note de qualité
29Institutions déclarées
10Pays d’affiliation déclarés

Rattachement africain : fr, us, gb, it, si, se, no, rs, nl, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: Ultrasonography (US) is sensitive for detecting echostructural abnormalities of the major salivary glands (SGs) in primary Sjögren's syndrome (pSS). Our objectives were to define selected US-SG echostructural abnormalities in pSS, set up a preliminary atlas of these definitions and evaluate the consensual definitions reliability in both static and acquisition US-SG images. METHODS: International experts in SG US in pSS participated in consensus meetings to select and define echostructural abnormalities in pSS. The US reliability of detecting these abnormalities was assessed using a two-step method. First 12 experts used a web-based standardised form to evaluate 60 static US-SG images. Intra observer and interobserver reliabilities were expressed in κ values. Second, five experts, who participated all throughout the study, evaluated US-SG acquisition interobserver reliability in pSS patients. RESULTS: Parotid glands (PGs) and submandibular glands (SMGs) intra observer US reliability on static images was substantial (κ > 0.60) for the two main reliable items (echogenicity and homogeneity) and for the advised pSS diagnosis. PG inter observer reliability was substantial for homogeneity. SMGs interobserver reliability was moderate for homogeneity (κ = 0.46) and fair for echogenicity (κ = 0.38). On acquisition images, PGs interobserver reliability was substantial (κ = 0.62) for echogenicity and moderate (κ = 0.52) for homogeneity. The advised pSS diagnosis reliability was substantial (κ = 0.66). SMGs interobserver reliability was fair (0.20< κ ≤ 0.40) for echogenicity and homogeneity and either slight or poor for all other US core items. CONCLUSION: This work identified two most reliable US-SG items (echogenicity and homogeneity) to be used by US-SG trained experts. US-PG interobserver reliability result for echogenicity is in line with diagnosis of pSS.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Salivary gland ultrasound abnormalities in primary Sjögren’s syndrome: consensual US-SG core items definition and reliability
Date Crossref
01/06/2017
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Salivary Gland Disorders and FunctionsSalivary Gland Tumors Diagnosis and TreatmentSystemic Sclerosis and Related Diseases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.