Microinvasive Glaucoma Stent (MIGS) Surgery With Concomitant Phakoemulsification Cataract Extraction: Outcomes and the Learning Curve
Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: To evaluate learning effects with respect to outcomes of a microinvasive glaucoma stent (MIGS) inserted during cataract surgery in glaucoma patients. PATIENTS AND METHODS: Single surgeon, observational cohort study of 25 consecutive Ivantis Hydrus microstent insertions, with a minimum follow-up of 12 months. A learning curve analysis was performed by assessing hypotensive effect, adverse effects, and surgical procedure duration, with respect to consecutive case number. Success was defined with respect to various intraocular pressure (IOP) targets (21, 18, 15 mm Hg) and reduction in required antiglaucoma medications. Complete success was defined as achieving target IOP without antiglaucoma therapy. RESULTS: No clinically significant adverse events or learning effects were identified, although surgical time reduced with consecutive case number. Mean follow-up was 16.8 months. At final follow-up the mean IOP for all eyes was reduced from 18.1 (±3.6) mm Hg [and a simulated untreated value of 25.9 (±5.2) mm Hg] to 15.3 (±2.2) mm Hg (P=0.007; <0.0001) and the mean number of topical antiglaucoma medications was reduced from 1.96 (±0.96) to 0.04 (±0.20) (P<0.0001). Complete success (IOP<21 mm Hg, no medications) was 96% at final follow-up. Complete success (IOP<18 mm Hg, no medications) was 80% at final follow-up, but only 32% with a target IOP of <15 mm Hg (no medications). CONCLUSIONS: No significant learning curve effects were observed for a trained surgeon with respect to MIGS microstent insertion performed at the time of cataract surgery. Adjunctive MIGS surgery was successful in lowering IOP to <18 mm Hg and reducing/abolishing the requirement for antiglaucoma medication in eyes with open-angle glaucoma, but less successful at achieving low IOP levels (<15 mm Hg).
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Microinvasive Glaucoma Stent (MIGS) Surgery With Concomitant Phakoemulsification Cataract Extraction: Outcomes and the Learning Curve
- Date Crossref
- 01/07/2017
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.