Thickness and Closure Kinetics of the Suprachoroidal Space Following Microneedle Injection of Liquid Formulations

39Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Purpose: To determine the effect of injection volume and formulation of a microneedle injection into the suprachoroidal space (SCS) on SCS thickness and closure kinetics. Methods: Microneedle injections containing 25 to 150 μL Hanks' balanced salt solution (HBSS) were performed in the rabbit SCS ex vivo. Distribution of SCS thickness was measured by ultrasonography and three-dimensional (3D) cryo-reconstruction. Microneedle injections were performed in the rabbit SCS in vivo using HBSS, Discovisc, and 1% to 5% carboxymethyl cellulose (CMC) in HBSS. Ultrasonography was used to track SCS thickness over time. Results: Increasing HBSS injection volume increased the area of expanded SCS, but did not increase SCS thickness ex vivo. With SCS injections in vivo, the SCS initially expanded to thicknesses of 0.43 ± 0.06 mm with HBSS, 1.5 ± 0.4 mm with Discovisc, and 0.69 to 2.1 mm with 1% to 5% CMC. After injection with HBSS, Discovisc, and 1% CMC solution, the SCS collapsed to baseline with time constants of 19 minutes, 6 hours, and 2.4 days, respectively. In contrast, injections with 3% to 5% CMC solution resulted in SCS expansion to 2.3 to 2.8 mm over the course of 2.8 to 9.1 hours, after which the SCS collapsed to baseline with time constants of 4.5 to 9.2 days. Conclusions: With low-viscosity formulations, SCS expands to a thickness that remains roughly constant, independent of the volume of fluid injected. Increasing injection fluid viscosity significantly increased SCS thickness. Expansion of the SCS is hypothesized to be controlled by a balance between the viscous forces of the liquid formulation and the resistive biomechanical forces of the tissue.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Thickness and Closure Kinetics of the Suprachoroidal Space Following Microneedle Injection of Liquid Formulations
Date Crossref
26/01/2017
Éditeur
Association for Research in Vision and Ophthalmology (ARVO)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advancements in Transdermal Drug DeliveryGlaucoma and retinal disordersRetinal and Macular Surgery

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.