Leak rate estimation of a resistive plate chamber gap by monitoring absolute pressure
Rattachement africain : in. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The differential pressure of a conventional manometer is highly dependent on the atmospheric pressure. The measurements with a manometer for an extended time period show a large variation due to solar atmospheric tides. However, the measurements of absolute pressure, both outside and inside of a resistive plate chamber (RPC), are independent of each other. By monitoring the absolute pressures, both outside and inside of a RPC, along with the temperature, its leakage rate can be estimated. During the test period, the supporting button spacers inside a RPC may get detached due to some manufacturing defect. This effect can be detected clearly by observing the sudden fall of pressure inside the chamber.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Leak rate estimation of a resistive plate chamber gap by monitoring absolute pressure
- Date Crossref
- 09/11/2016
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.