Aller au contenu principal
Accès ouvert déclaré 2016 article

Whole lung lavage therapy for pulmonary alveolar proteinosis: a global survey of current practices and procedures

165Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
6Pays d’affiliation déclarés

Rattachement africain : it, us, de, nl, jp, fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Whole lung lavage (WLL) is the current standard of care treatment for patients affected by pulmonary alveolar proteinosis (PAP). However, WLL is not standardized and international consensus documents are lacking. Our aim was to obtain a factual portrayal of WLL as currently practiced with respect to the procedure, indications for its use, evaluation of therapeutic benefit and complication rate. METHODS: A clinical practice survey was conducted globally by means of a questionnaire and included 27 centers performing WLL in pediatric and/or adult PAP patients. RESULTS: We collected completed questionnaires from 20 centres in 14 countries, practicing WLL in adults and 10 centers in 6 countries, practicing WLL in pediatric patients. WLL is almost universally performed under general anesthesia, with a double-lumen endobronchial tube in two consecutive sessions, with an interval of 1-2 weeks between sessions in approximately 50 % of centres. The use of saline warmed to 37 °C, drainage of lung lavage fluid by gravity and indications for WLL therapy in PAP were homogenous across centres. There was great variation in the choice of the first lung to be lavaged: 50 % of centres based the choice on imaging, whereas 50 % always started with the left lung. The choice of position was also widely discordant; the supine position was chosen by 50 % of centres. Other aspects varied significantly among centres including contraindications, methods and timing of follow up, use of chest percussion, timing of extubation following WLL and lung isolation and lavage methods for small children. The amount of fluid used to perform the WLL is a critical aspect. Whilst a general consensus exists on the single aliquot of fluid for lavage (around 800 ml of warm saline, in adults) great variability exists in the total volume instilled per lung, ranging from 5 to 40 liters, with an average of 15.4 liters/lung. CONCLUSIONS: This international survey found that WLL is safe and effective as therapy for PAP. However these results also indicate that standardization of the procedure is required; the present survey represents the a first step toward building such a document.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Whole lung lavage therapy for pulmonary alveolar proteinosis: a global survey of current practices and procedures
Date Crossref
31/08/2016
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Neonatal Respiratory Health ResearchRespiratory Support and MechanismsCongenital Diaphragmatic Hernia Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.