Correction of CAPD Catheter Displacement Using Gastric Biopsy Forceps: The Push-Pull Method
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
We corrected malpositioned continuous ambulatory peritoneal dialysis catheters in six patients using a new technique named the "push-pull method". A gastric biopsy forceps was advanced through the catheter to near its tip. After manipulating the tip of the forceps through the abdominal wall, the forceps was opened and pulled out slowly. Repeated insertion and removal of the forceps induced the catheter to return to the pelvic cavity. This push-pull method was successful for Swan neck straight (n=2) and coiled (n=4) catheters in all patients. The time required for the procedure was only 5-10 minutes and there were no complications.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Correction of CAPD Catheter Displacement Using Gastric Biopsy Forceps: The Push-Pull Method
- Date Crossref
- 01/04/1999
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.