Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes (135Xe, 133Xe, 133mXe and 133mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at the end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report
- Date Crossref
- 07/11/2014
- Éditeur
- Office of Scientific and Technical Information (OSTI)
- Type
- report
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Pacific Northwest National Laboratory pays non établi dans la noticeStructure de recherche
-
Pacific Northwest National Lab. (PNNL) pays non établi dans la noticeInstitution
Pacific Northwest National Laboratory et Pacific Northwest National Lab. (PNNL).
Une affiliation ne permet pas de déduire la nationalité d’un auteur.