An In Vitro Investigation of Veneered Zirconia‐Based Restorations Shade Reproducibility
Rattachement africain : jo, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Purpose To examine the effects of the veneering technique on the shade reproducibility of zirconia‐based crowns. Materials and Methods An artificial tooth was prepared with a 1.2 mm heavy chamfer finish line and 8° taper. The prepared tooth was scanned using CAD/CAM technology to fabricate 45 cobalt chromium (CoCr) testing dies. One CoCr die was scanned, and 45 zirconia copings were milled and devided according to the veneering technique into 3 groups of 15 specimens each: layering veneering (LV) using Vita Vm9, overpressing veneering (OV) using Vita Pm9, and digital veneering (DV) using Vita Triluxe forte. All veneering layers had the same shade (A2). The specimens were cemented onto the testing dies using glass inomer cement. A spectrophotometer was used to measure the shade coordinates (L, C, h, a, b) for a Vita A2 shade tab and for each specimen. Both the CIE Lab (ΔEab) and the CIE DE2000 (ΔE00) color difference formulas were applied to compare the shade tab and the study groups. One‐way ANOVA and multiple comparison Bonferroni tests were applied for statistical analysis of the results. Results Means and standard deviations (SDs) of ΔEab were 2.3 ± 1.3 for LV, 3.5 ± 0.8 for OV, and 4.0 ± 0.7 for DV. Means and SDs of ΔE00 were 1.4 ± 0.8 for LV, 2.1 ± 0.5 for OV, and 3.1 ± 0.4 for DV. ΔEab of LV group was significantly lower (p < 0.05) than both OV and DV groups, whereas the difference in ΔEab between OV and DV groups was not significant (p = 0.39). The differences in ΔE00 between all groups were significant (p < 0.05). Conclusions LV group was superior to other groups in terms of shade reproducibility. The ΔEab and the ΔE00 values of LV and OV groups were within clinically acceptable ranges; however, the ΔEab and the ΔE00 values of group DV were beyond the clinically acceptable ranges. The ΔE00 formula demonstrated a statistically significant difference between OV and the DV groups, while the ΔEab formula did not. The zirconia veneering technique had a significant influence on the shade reproducibility of zirconia‐based crowns.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- An In Vitro Investigation of Veneered Zirconia‐Based Restorations Shade Reproducibility
- Date Crossref
- 09/05/2016
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.