Aller au contenu principal
2014 conference-abstract

177 New Designs of Ventricular Catheters for Hydrocephalus by 3-Dimensional Computational Fluid Dynamics

1Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

INTRODUCTION: Based on a landmark study by Lin et al of the 2-dimensional flow in ventricular catheters (VC) via computational fluid dynamics (CFD), we studied in a previous paper the 3-dimensional flow patterns of 5 commercially available VC. We calculated that most of the total fluid mass flows through the catheter's most proximal holes. In this paper we design 5 VC prototypes with equalized flow characteristics. METHODS: We study 5 prototypes of VC by means of CFD in 3-dimensional (3-D) automated models and compare the fluid-mechanical results with our previous study of currently in use VC. The general procedure for the development of a CFD model calls for transforming the physical dimensions of the system to be studied into a virtual wire-frame model which provides the coordinates for the virtual space of a CFD mesh. The incompressible Navier-Stokes equations, a system of strongly coupled, nonlinear, partial differential conservation equations governing the motion of the flow field, are then solved numerically. RESULTS: By varying the number of drainage holes and the ratio hole/segment, whether with a simple or tapered hole type, we obtained improved flow characteristics in 5 prototypes of VC. In particular, we equalized the flow pattern through the different hole segments of the new VC prototypes, as disclosed by 3-D CFD. CONCLUSION: New catheter designs with variable hole diameter, number of holes, and ratio hole/segment along the catheter allow the fluid to enter the catheter more uniformly along its length, thus reducing the chance of its becoming occluded.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
177 New Designs of Ventricular Catheters for Hydrocephalus by 3-Dimensional Computational Fluid Dynamics
Date Crossref
01/08/2014
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Traffic control and managementReinforcement Learning in RoboticsCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.