Aller au contenu principal
Accès ouvert déclaré 2014 article

Computer-Aided Detection for Computed Tomographic Colonography Screening

21Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: The objective of this study was to prospectively compare diagnostic performance and time efficiency of a double-reading paradigm in which a first-reader computer-aided detection (CAD) is followed by a fast 2-dimensional review (DR FR-CAD) with those of a double reading with second-reader CAD (SR CAD). MATERIALS AND METHODS: The local ethical committee approved this study. Consecutive immunological patients who have positive results for fecal immunological test who were scheduled for colonoscopy were enrolled for a 10-month period. Computed tomographic colonography studies were read with CAD (CAD COLON-1.20; im3D, Turin, Italy) by using both SR CAD (applied after unassisted interpretation primary 2-dimensional) and DR FR-CAD (CAD-prompts evaluation followed by a fast 2-dimensional review) in randomized order with the radiologist for each reading paradigm masked to the other reader's results.Per-patient sensitivity and specificity of unassisted and CAD-assisted readings for detecting 6-mm adenomas or larger were calculated by using unblinding colonoscopy as reference standard. Reporting times were also calculated. Pairwise comparisons were performed. RESULTS: A total of 182 participants (median age, 65 years; range, 58-76) were included in the final analysis. Of these, 93 (51%) had at least 1 cancer or a 6-mm adenoma or larger. At the 6-mm threshold, sensitivity of unassisted reading (79.6%; 95% confidence interval [CI], 69.9-87.2) increased significantly with the use of both SR CAD (86.0%; 95% CI, 77.3%-92.3%) and DR FR-CAD (89.2%; 95% CI, 81.1%-94.7%), without differences between CAD readings (P = 0.500). No significant differences in specificity among the 3 paradigms were observed. Double reading with first-reader CAD required less reading time than that for SR CAD (378 vs 496; Δ118 seconds; P < 0.001) and was 59 seconds longer than the unassisted reading (P = 0.058). CONCLUSIONS: When compared with unassisted reading, a double-reading paradigm in which first-reader CAD is followed by a fast 2-dimensional review improves the adenoma detection rate to the same level achieved by a second-reader CAD while decreasing reporting times.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Computer-Aided Detection for Computed Tomographic Colonography Screening
Date Crossref
01/03/2014
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Colorectal Cancer Screening and DetectionAI in cancer detectionCOVID-19 diagnosis using AI

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.