Accuracy of 18F-FDG PET/CT, Multidetector CT, and MR Imaging in the Diagnosis of Pancreatic Cysts: A Prospective Single-Center Study
Rattachement africain : fi. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
UNLABELLED: Accurate diagnosis of the nature of pancreatic cysts is challenging but more important than ever, in part because of the increasing number of incidental cystic findings in the pancreas. Preliminary data suggest that (18)F-FDG PET/CT may have a significant influence on clinical decision making, although its role is still evolving. Our aim was to prospectively compare the accuracy of combined (18)F-FDG PET and contrast-enhanced CT ((18)F-FDG PET/CT), multidetector CT (MDCT), and MR imaging in differentiating malignant from benign pancreatic cysts. METHODS: Thirty-one consecutive patients with pancreatic cysts were enrolled in the study. They underwent a protocol including (18)F-FDG PET/CT, MDCT, and MR imaging combined with MR cholangiopancreatography, all of which were evaluated in a masked manner. The findings were confirmed macroscopically at surgery or histopathologic analysis (n = 22) or at follow-up (n = 9). RESULTS: Of the 31 patients, 6 had malignant and 25 had benign lesions. The diagnostic accuracy was 94% for (18)F-FDG PET/CT, compared with 77% and 87% for MDCT (P < 0.05) and MR imaging, respectively. (18)F-FDG PET/CT had a negative predictive value of 100% and a positive predictive value of 75% for pancreatic cysts. The maximum standardized uptake value was significantly higher in malignant (7.4 ± 2.6) than in benign lesions (2.4 ± 0.8) (P < 0.05). When the maximum standardized uptake value was set at 3.6, the sensitivity and specificity were 100% and 88%, respectively. Furthermore, when compared with MDCT and MR imaging, respectively, (18)F-FDG PET/CT altered the clinical management of 5 and 3 patients, respectively. CONCLUSION: (18)F-FDG PET/CT is an accurate imaging modality for differentiating between benign and malignant pancreatic cysts. We recommend the use of (18)F-FDG PET/CT in the evaluation of diagnostically challenging pancreatic cysts.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Accuracy of <sup>18</sup>F-FDG PET/CT, Multidetector CT, and MR Imaging in the Diagnosis of Pancreatic Cysts: A Prospective Single-Center Study
- Date Crossref
- 04/06/2015
- Éditeur
- Society of Nuclear Medicine
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Turku University Hospital Division of Digestive Surgery and Urology pays non établi dans la noticeÉtablissement de santé
-
Turku PET Centre pays non établi dans la noticeStructure de recherche
-
Tampere University Hospital Department of Radiology pays non établi dans la noticeÉtablissement de santé
-
Tampere University pays non établi dans la noticeUniversité ou école supérieure
-
University of Turku Department of Medicine pays non établi dans la noticeUniversité ou école supérieure
-
Department of Clinical Physiology and Nuclear Medicine pays non établi dans la noticeÉtablissement de santé
Division of Digestive Surgery and Urology — Turku University Hospital, Turku PET Centre et Department of Radiology — Tampere University Hospital, avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.