Aller au contenu principal
Accès ouvert déclaré 2015 article

Detection of G119S ace-1 R mutation in field-collected Anopheles gambiae mosquitoes using allele-specific loop-mediated isothermal amplification (AS-LAMP) method

35Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : Burkina Faso, jp, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Malaria vectors have developed resistance to the four families of insecticides available for public health purposes. For example, the kdr mutation is associated with organochlorines and pyrethroids resistance. It is of particular concern that organophosphate and carbamate resistance associated with the G119S ace-1 (R) mutation has recently increased in West Africa in extent and frequency, and is now spreading through the Anopheles gambiae malaria vector population. There is an urgent need to improve resistance management using existing insecticides and new tools to quickly assess resistance level for rapid decision-making. METHODS: DNA extracted from field-collected mosquitoes was used to develop the method. Specific primers were designed manually to match the mutation region and an additional mismatched nucleotide in the penultimate position to increase specificity. Other primers used are common to both wild and mutant types. The allele specific (AS)-LAMP method was compared to the PCR restriction fragment length polymorphism (PCR-RFLP) and real-time PCR (RT-PCR) methods using the genomic DNA of 104 field-collected mosquitoes. RESULTS: The primers designed for LAMP were able to distinguish between the wild type (ace-1 (S) ) and mutated type allele (ace-1 (R) ). Detection time was 50 min for the wild type homozygous and 64 min for the heterozygous. No amplification of the resistant allele took place within the 75-min test period when using the wild type primers. For the ace-1 (R) resistant type, detection time was 51 min for the resistant homozygous and 55 min for the heterozygous. No amplification of the wild type allele took place within the 75-min test period when using the resistant type primers. Gel electrophoresis of LAMP products confirmed that amplification was primer-DNA specific, i.e., primers could only amplify their target specific DNA. AS-LAMP, PCR-RFLP, and RT-PCR showed no significant difference in the sensitivity and specificity of their ace-1 (R) detection ability. CONCLUSIONS: The AS-LAMP method could detect the ace-1 (R) mutation within 60 min, which is faster than conventional PCR-RFLP. This method may be used to quickly detect the ace-1 (R) mutation for rapid decision-making, even in less well-equipped laboratories.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Detection of G119S ace-1 R mutation in field-collected Anopheles gambiae mosquitoes using allele-specific loop-mediated isothermal amplification (AS-LAMP) method
Date Crossref
01/12/2015
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Malaria Research and ControlBiosensors and Analytical DetectionMosquito-borne diseases and control

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.