Aller au contenu principal
2010 article

Stability of Intravenous Flucloxacillin Solutions used for Hospital‐in‐the‐Home

14Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

ABSTRACT Background Despite the uncertainty regarding flucloxacillin's stability, flucloxacillin solutions are routinely used as 24‐hour ambulatory infusions for hospital‐in‐the‐home patients. Aim To determine the stability of flucloxacillin solutions in a simulated hospital‐in‐the‐home environment and to assess whether flucloxacillin loss can be minimised via pH control. Method Samples of flucloxacillin 5% and 12% solutions were prepared with either sodium chloride 0.9% or water for injection and with or without 5 mL phosphate buffer (0.384 M; pH 7). Flucloxacillin 5% solutions were tested in elastomeric infusion devices and the 12% solutions in polyvinyl chloride bags. All of the solutions were refrigerated for 6 days and then half of them were incubated at 37 °C for 24 hours. The remainder of the refrigerated solutions acted as controls. Incubated solutions were sampled for pH and high performance liquid chromatography analysis on Day 0, and Day 6 at 0, 12, 18 and 24 hours. Controls were sampled on Days 0, 6 and 14. Acceptable shelf life was ± 7.5% of initial flucloxacillin content. Results Refrigerated buffered controls remained stable for 14 days while the unbuffered controls were stable for 6 days. All of the buffered solutions were stable at 37 °C after 24 hours, except for flucloxacillin 12% in water for injection. Incubated unbuffered flucloxacillin 5% in water for injection lost approximately 27% flucloxacillin and all of the other incubated unbuffered solutions lost up to 60%. Incubated unbuffered solutions displayed significant yellowing and cloudiness. The pH of all solutions fell by approximately 1 unit, except for refrigerated buffered controls (fell by 0.5 units). Conclusion Unbuffered flucloxacillin 5% and 12% solutions lost up to 60% of flucloxacillin content when stored at 37 °C for 24 hours. Adjusting pH with phosphate buffer kept the incubated solutions stable for at least 24 hours (except flucloxacillin 12% in water for injection).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Stability of Intravenous Flucloxacillin Solutions used for Hospital‐in‐the‐Home
Date Crossref
01/06/2010
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Antibiotics Pharmacokinetics and EfficacyAntimicrobial Resistance in StaphylococcusPharmaceutical studies and practices

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.