Aller au contenu principal
2008 article

Determination of Morphine and 6-Acetylmorphine in Blood With Use of Dried Blood Spots

117Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The use of dried blood spots (DBS) which has successfully been introduced in neonatal metabolic screening is an appropriate method to reduce virus infection risk to a minimum, facilitating regular mailing and handling of samples in the laboratory. Injection diacetylmorphine use is notably associated with a prevalence of infection and a risk of transmission of blood-borne viruses. The aim of the present study was to establish a method to determine morphine and 6-acetylmorphine (6-AM) as accurately and sensitively from DBS as from whole blood. Analysis by liquid chromatography/tandem mass spectrometry was checked for carryover, ion suppression/enhancement, linearity of response, lower limits of detection and quantification, and the within-run and between-run assay imprecision for both whole blood and DBS after liquid/liquid extraction. DBS drying time and elution were optimized, and extraction efficiency from DBS was compared with that of blood and of a solution of the pure compounds. Short-term stability of morphine and 6-AM was determined at -20 degrees C, 4 degrees C, and 40 degrees C up to 7 days from both whole blood and DBS. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating 50 authentic samples. The lower limit of detection was 0.4 ng of morphine per spot and 0.8 ng of 6-AM per spot using a DBS blood volume of 100 microL and was 0.3 and 0.7 ng/100 microL whole blood for morphine and 6-AM, respectively. Recovery rates of the analytes from DBS did not differ from those from whole blood and were > or =55% for 6-AM and > or =25% for morphine, and the within- and between-run coefficients of variation were always < or =9%. 6-AM degraded rapidly at both 4 degrees C and 40 degrees C in whole blood; however, it seemed to be much more stable in DBS. Significant correlations between real whole-blood samples and DBS were obtained. The DBS assay has potential as a precise and inexpensive option for the determination of morphine and 6-AM in small blood samples. Further, the DBS matrix proved to excellently stabilize 6-AM.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Determination of Morphine and 6-Acetylmorphine in Blood With Use of Dried Blood Spots
Date Crossref
01/12/2008
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Biosimilars and Bioanalytical MethodsBlood groups and transfusionBlood disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.