Pacemaker clinic: an opportunity to detect silent atrial fibrillation and improve antithrombotic treatment
Rattachement africain : es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
AIMS: The prevalence of atrial fibrillation (AF) in patients with pacemakers is high, and often passes unnoticed. Our aim was to assess the use of antithrombotic treatment in this group of patients. METHODS AND RESULTS: All patients who came to our institution to have their pacemakers checked during the year 2008 were included in this study. The atrial activity was assessed by slowing down the paced frequency if necessary, and by the analysis of atrial electrograms in atrial-based pacemakers. The appropriateness of the antithrombotic treatment was evaluated by a cardiologist. Out of 585 patients, 216 (36.9%) displayed AF at some point during the 5.5-year monitoring period (1.5-11), although only 58 (9.9%) displayed it at the time of the implant. Of these 216, 58% were men, with an average age of 80 years (76-86 years). The pacemaker was implanted in response to an atrioventricular block (AVB) in 46.3% of the cases, sinoatrial node disorder in 24.1% of the cases, and slow AF in 25.9% of the cases. The CHADS2 score was 0 points in 4.2% (9) of the cases, 1 point in 19% (41) of the cases, and ≥ 2 points in 77% (173) of the cases. Despite this, only 58.3% of the cases received anticoagulant treatment. The existence of arrhythmia at the time of implantation [odds ratio (OR) = 4.25; 95% confidence interval (95% CI), 1.72-10.51; P = 0.002] and the implantation of a pacemaker with atrioventricular synchronization (OR = 13.23; 95% CI, 2.89-60.56; P = 0.001) were associated with the use of anticoagulant treatment in those cases with CHADS2>2. CONCLUSION: Atrial fibrillation is common in patients fitted with pacemakers. Despite the high risk of embolism, an underuse of anticoagulant treatment was observed.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Pacemaker clinic: an opportunity to detect silent atrial fibrillation and improve antithrombotic treatment
- Date Crossref
- 28/06/2011
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.