Aller au contenu principal
Accès ouvert déclaré 2012 article

Efficacy of Computer-aided Detection as a Second Reader for 6–9-mm Lesions at CT Colonography: Multicenter Prospective Trial

43Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To assess the effect of computer-aided detection (CAD) as a second reader on the sensitivity and specificity of computed tomographic (CT) colonography in detecting 6-9-mm colorectal cancer (CRC) lesions. MATERIALS AND METHODS: Individuals with clinical indications for colonoscopy--either for symptoms or as part of participating in a surveillance program or CRC screening--were prospectively enrolled at one of 10 academic centers between July 2007 and May 2009. Institutional review board approval was obtained at each clinical site, and all participants provided written informed consent. All participants underwent CT colonography and colonoscopy on the same day. Experienced readers interpreted the CT colonography images unassisted and then reviewed all colorectal lesion-like structures pinpointed by the CAD algorithm. Segmental unblinding of CT colonoscopy findings at colonoscopy was utilized. The sensitivity and specificity of unassisted and CAD-assisted reading in identifying individuals with 6-9-mm lesions were calculated and compared by means of pairwise analysis. RESULTS: A total of 618 participants (mean age, 57.9 years; 54.5% male) were included in the final analysis. Of these participants, 464 (75.1%) had no lesions 6 mm or larger, and 52 (8.4%) had 6-9-mm lesions. The sensitivity of CT colonography with unassisted reading and that with CAD-assisted reading in identifying individuals with 6-9-mm lesions was 65.4% (95% confidence interval [CI]: 50.9%, 78.0%) and 76.9% (95% CI: 63.2%, 87.5%; P = .016), respectively. No significant change in specificity was observed: The specificity of CT colonography with unassisted and that with CAD-assisted reading was 91.8% (95% CI: 88.9%, 94.1%) and 90.9% (95% CI: 88.0%, 93.4%; P = .063), respectively. Evaluation of CAD candidates required an additional 1.6 minutes (25th-75th percentile: 1.0 minute to 3.4 minutes). CONCLUSION: The addition of CAD to reading performed by experienced readers resulted in a significant benefit in the detection of 6-9-mm polyps at CT colonography in this cohort. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120376/-/DC1.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Efficacy of Computer-aided Detection as a Second Reader for 6–9-mm Lesions at CT Colonography: Multicenter Prospective Trial
Date Crossref
01/01/2013
Éditeur
Radiological Society of North America (RSNA)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Colorectal Cancer Screening and DetectionAI in cancer detectionCOVID-19 diagnosis using AI

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.