Accuracy of 64-Multidetector-Row Computed Tomography in the Diagnosis of Coronary Artery Disease
Rattachement africain : kw. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVES: The aim of this prospective study was to assess the accuracy of 64-multidetector-row computed tomography coronary angiography (CTA) in the diagnosis of coronary artery disease (CAD). PATIENTS AND METHODS: Ninety-two patients suspected of having CAD underwent CTA using a 64-slice CT scanner before a scheduled, conventional coronary angiogram (CCA). Blinded assessment of CTA to detect CAD was performed. The accuracy of CTA in detecting significant stenoses (> or =50%) was compared to CCA. Data analysis was performed on 73 patients because the scans were nondiagnostic in 5 patients and 14 refused to undergo coronary angiography. RESULTS: The CTAs of 21 of these 73 patients were considered as normal; 19 were confirmed on CCA. For the remaining 52 diagnosed as abnormal, 51 were confirmed on CCA. For patient-based analysis, CTA had a sensitivity of 95%, a specificity of 96%, a positive predictive value of 98% and a negative predictive value of 90%. For the whole vessel, the sensitivity of CTA was 60-100%, for all vessels and the specificity was 82-100%. Pooled sensitivity was 92% and pooled specificity was 98%. For the segments, the sensitivity of CTA was 64% or above for all vessels except for the distal left anterior descending artery (40%), mid circumflex artery (50%) and posterior descending artery (60%); the pooled sensitivity was 79%. The specificity for the segments was 82-100% for all vessels and pooled specificity was 94%. CONCLUSION: The sensitivity and specificity for patient-based analysis and for the main coronary vessels were high whereas for the segments, the sensitivity was moderately good, but the specificity was high, confirming that a negative CTA is useful to rule out significant CAD. A coordinated classification system between radiologists and cardiologists is required to eliminate errors in segment classification.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Accuracy of 64-Multidetector-Row Computed Tomography in the Diagnosis of Coronary Artery Disease
- Date Crossref
- 01/01/2009
- Éditeur
- S. Karger AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.