Real-time ultrasound elasticity imaging for liver RF ablation assessment: Preliminary ex vivo and in vivo animal studies

2Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, fi. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

In this study, a real-time compression based ultrasound elasticity imaging prototype was developed and evaluated for liver radio-frequency ablation (RFA) assessment under ex vivo and in vivo conditions. The prototype was implemented on a commercial ultrasound system (iU22, Philips Healthcare) for an L12-5 linear transducer and a C5-1 curvilinear transducer. Under the ex vivo condition, two bovine liver samples were used for L12-5 and C5-1 respectively. Under the in vivo condition, a pig was anesthetized and mechanically ventilated. Ultrasound elasticity imaging experiments were performed during breath-hold in order to reduce respiratory motion artifacts. Post-RFA strain images were compared against several imaging modalities including MRI, contrast-enhanced CT and gross pathology. For the ex vivo case, a Rita Starburst probe (AngioDynamics, Queensbury, NY) was used to perform RFA and induce tissue deformation for strain imaging. Real-time strain images were generated pre- and post-RFA. After the ablation, the liver was imaged by a Panorama 1-T MRI system (Philips Healthcare), then it was dissected along the approximate ultrasound imaging plane for lesion dimension measurement using a caliper. The post-RFA strain images depicted an ablation zone with increased stiffness that was well correlated with the physiological changes observed in the T1-weighted MR image and gross pathology. For the second ex vivo liver sample, the strain image revealed an ablation zone of 4.90 cm ? 2.85 cm, and the MR image and gross pathology showed a zone of 4.56 cm ? 3.24 cm and of 4.91 cm ? 3.65 cm, respectively. For the in vivo study, three different commercial RFA needles were employed: the Covidien (Mansfield, MA) CoolTip single prong and triple-cluster probes, and the Rita Starburst probe. The animal underwent contrast-enhanced CT imaging immediately after RFA. It was then sacrificed and the ablated liver lobes were dissected for ex vivo MRI. All three imaging modalities showed comparable measurement of lesion dimensions. The triple-cluster Covidien probe and the Rita probe with expanding tines seemed to perform better with elasticity assessment than the Covidien single prong probe. Preliminary results from this study demonstrate that real-time ultrasound strain imaging is potentially a valuable tool for assessing liver RFA. Further technical development of this prototype will advance toward real-time clinical use.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Real-time ultrasound elasticity imaging for liver RF ablation assessment: Preliminary ex vivo and in vivo animal studies
Date Crossref
01/09/2009
Éditeur
IEEE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ultrasound Imaging and ElastographyUltrasound and Hyperthermia ApplicationsUltrasonics and Acoustic Wave Propagation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.