Suture Anchor Fixation of Bony Bankart Fractures
Rattachement africain : ca, ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: As an alternative to the standard single-point suture-anchor technique, a suture-bridge technique has been described for the treatment of bony Bankart fractures. There is, however, little evidence supporting one technique over the other. Purpose/ HYPOTHESIS: To compare the failure strength, fixation stability, and loading mechanics of the 2 techniques for the fixation of bony Bankart fractures. We hypothesized that use of the double-point suture-bridge technique would result in superior strength and fixation stability because of the increased compression and contact area between the bony fragment and glenoid fracture site. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 16 shoulders (8 pairs) were tested with an intact glenoid, after creation of a 15% bony Bankart fracture, and after fragment fixation using a single-point or suture-bridge technique. Paired specimens were randomly assigned to each technique. Cyclic progressive loading was applied via a materials testing machine to the glenoid concentrically and eccentrically according to a staircase protocol. Failure strength, fragment displacement, glenoid strain load transfer, and contact area were quantified. RESULTS: No significant differences in failure strength were found between the single-point and suture-bridge techniques (mean strength, 74 ± 28 N vs 77 ± 56 N, respectively; P = .91). Additionally, no significant differences were found for glenoid load transfer (P ≥ .318) and glenohumeral joint contact (P = .357) between the 2 techniques. Centralized loading, however, produced significant differences in fragment displacement at 5, 150, and 200 N (P ≤ .045), with the single-point technique permitting greater fragment displacement in all cases (0.06-0.28 mm). Similarly, eccentric loading caused significantly greater fragment displacement with the single-point technique at ≥25 N compared with the suture-bridge technique (mean range, 0.38-0.63 mm vs 0.14-0.19 mm, respectively; .009 ≤ P ≤ .048). CONCLUSION: Single-point and suture-bridge techniques for the fixation of bony Bankart fragments have equivalent failure strengths and load transfers. The suture-bridge technique does provide statistically greater initial fracture fragment stability; however, the clinical implications of this are presently unknown. CLINICAL RELEVANCE: This study will aid in the selection of the optimal repair technique for bony Bankart fractures by providing important insights into the quality of initial fixation and ultimate strength.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Suture Anchor Fixation of Bony Bankart Fractures
- Date Crossref
- 05/09/2013
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Western University pays non établi dans la noticeUniversité ou école supérieure
-
St Joseph's Health Care pays non établi dans la noticeÉtablissement de santé
-
Universitätsklinik Balgrist pays non établi dans la noticeÉtablissement de santé
-
The Hand and Upper Limb Centre pays non établi dans la noticeInstitution
-
Balgrist University Hospital pays non établi dans la noticeUniversité ou école supérieure
Western University, St Joseph's Health Care et Universitätsklinik Balgrist, avec 2 autres affiliations.