In Vivo Noninvasive Characterization of Brown Adipose Tissue Blood Flow by Contrast Ultrasound in Mice
Rattachement africain : be, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Interventions to increase brown adipose tissue (BAT) volume and activation are being extensively investigated as therapies to decrease the body weight in obese subjects. Noninvasive methods to monitor these therapies in animal models and humans are rare. We investigated whether contrast ultrasound (CU) performed in mice could detect BAT and measure its activation by monitoring BAT blood flow. After validation, CU was used to study the role of uncoupling protein 1 and nitric oxide synthases in the acute regulation of BAT blood flow. METHODS AND RESULTS: Blood flow of interscapular BAT was assessed in mice (n=64) with CU by measuring the signal intensity of continuously infused contrast microbubbles. Blood flow of BAT estimated by CU was 0.5±0.1 (mean±SEM) dB/s at baseline and increased 15-fold during BAT stimulation by norepinephrine (1 µg·kg(-1)·min(-1)). Assessment of BAT blood flow using CU was correlated to that performed with fluorescent microspheres (R(2)=0.86, P<0.001). To evaluate whether intact BAT activation is required to increase BAT blood flow, CU was performed in uncoupling protein 1-deficient mice with impaired BAT activation. Norepinephrine infusion induced a smaller increase in BAT blood flow in uncoupling protein 1-deficient mice than in wild-type mice. Finally, we investigated whether nitric oxide synthases played a role in acute norepinephrine-induced changes of BAT blood flow. Genetic and pharmacologic inhibition of nitric oxide synthase 3 attenuated the norepinephrine-induced increase in BAT blood flow. CONCLUSIONS: These results indicate that CU can detect BAT in mice and estimate BAT blood flow in mice with functional differences in BAT.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- In Vivo Noninvasive Characterization of Brown Adipose Tissue Blood Flow by Contrast Ultrasound in Mice
- Date Crossref
- 01/09/2012
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Ghent University VIB Department for Molecular Biomedical Research pays non établi dans la noticeUniversité ou école supérieure
-
Massachusetts General Hospital Department of Pediatrics pays non établi dans la noticeÉtablissement de santé
-
E.S.B.) and Cardiac Ultrasound Laboratory Department of Anesthesia pays non établi dans la noticeStructure de recherche
VIB Department for Molecular Biomedical Research — Ghent University, Department of Pediatrics — Massachusetts General Hospital et Department of Anesthesia — E.S.B.) and Cardiac Ultrasound Laboratory.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.