Aller au contenu principal
Accès ouvert déclaré 2013 article

Carotid Stenting

93Citations signalées, ce qui n’est pas une note de qualité
23Institutions déclarées
8Pays d’affiliation déclarés

Rattachement africain : fr, at, de, ch, nl, gb, Mali, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND AND PURPOSE: Randomized clinical trials show higher 30-day risk of stroke or death after carotid artery stenting compared with surgery. We examined whether operator experience is associated with 30-day risk of stroke or death in the Carotid Stenting Trialists' Collaboration database. METHODS: The Carotid Stenting Trialists' Collaboration is a pooled individual patient database including all patients recruited in 3 randomized trials of stenting versus endarterectomy for symptomatic carotid stenosis (Endarterectomy Versus Angioplasty in patients with Symptomatic Severe Carotid Stenosis trial, Stent-Protected Angioplasty versus Carotid Endarterectomy trial, and International Carotid Stenting Study). Lifetime carotid artery stenting experience, lifetime experience in stenting procedures excluding the carotid, and annual number of procedures performed within the trial (in-trial volume), divided into tertiles, were used to measure operator experience. The outcome event was the occurrence of any stroke or death within 30 days of the procedure. The analysis was done per protocol. RESULTS: Among 1546 patients who underwent carotid artery stenting, 120 (7.8%) had a stroke or death within 30 days of the procedure. The 30-day risk of stroke or death did not differ according to operator lifetime carotid artery stenting experience (P=0.8) or operator lifetime stenting experience excluding the carotid (P=0.7). In contrast, the 30-day risk of stroke or death was significantly higher in patients treated by operators with low (mean ≤3.2 procedures/y; risk 10.1%; adjusted risk ratio=2.30 [1.36-3.87]) and intermediate annual in-trial volumes (3.2-5.6 procedures/y; 8.4%; adjusted risk ratio=1.93 [1.14-3.27]) compared with patients treated by high annual in-trial volume operators (>5.6 procedures/y; 5.1%). CONCLUSIONS: Carotid stenting should only be performed by operators with annual procedure volume ≥6 cases per year.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Carotid Stenting
Date Crossref
01/02/2014
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cerebrovascular and Carotid Artery DiseasesIntracranial Aneurysms: Treatment and ComplicationsPeripheral Artery Disease Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.