Acute Hemodynamic Effect of Left Ventricular Endocardial Pacing in Cardiac Resynchronization Therapy
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: During cardiac resynchronization therapy (CRT) device implantation, the pacing lead is usually positioned in the coronary sinus (CS) to stimulate the left ventricular (LV) epicardium. Transvenous LV endocardial pacing via transseptal puncture has been proposed as an alternative method. In the present study, we evaluated the acute hemodynamic effects of CRT through LV endocardial pacing in heart failure patients by analyzing LV pressure-volume relationships. METHODS AND RESULTS: LV pressure and volume data were determined via conductance catheter during CRT device implantation in 10 patients. In addition to the standard epicardial CS pacing, the following endocardial LV sites were systematically assessed: the site transmural to the CS lead, the LV apex, the septal midwall, the basal lateral free wall, and the midlateral free wall. Four atrioventricular delays were tested. There was a significant improvement of systolic function with CRT in all LV pacing configurations, whereas no differences in systolic or diastolic function were detected between LV epicardial and endocardial transmural sites. The optimal pacing site varied among patients but was rarely related to relatively longer activation delays, as assessed by analyzing endocardial electric activation maps. Nonetheless, positioning the pacing lead at the optimal endocardial LV site in each patient significantly improved LV performance in comparison with conventional CS site stimulation (stroke volume, 83 [79-112] mL versus 73 [62-89] mL; P=0.034). CONCLUSIONS: Pacing at the optimal individual LV endocardial site yields enhanced LV performance in comparison with conventional CS site stimulation. Endocardial LV pacing might constitute an alternative approach to CRT, when CS pacing is not viable.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Acute Hemodynamic Effect of Left Ventricular Endocardial Pacing in Cardiac Resynchronization Therapy
- Date Crossref
- 01/06/2012
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.