Performance of a Rate Responsive Accelerometer‐Based Pacemaker with Autocalibration During Standardized Exercise and Recovery

10Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The rate responsiveness of a single chamber, accelerometer-based pacemaker with an autocalibration function (Opus G VVIR pacemaker, ELA Medical) was studied with a daily life protocol developed to automatically optimize the programming of accelerometer-based sensors. This new sensor was compared with two other body activity sensors that were manually optimized patient by patient. Forty-three pacemaker recipients (mean age 71 +/- 11 years), paced > 95% of the time, underwent a daily life protocol consisting of rapid walking for 6 minutes (W), climbing upstairs for 1.5 minutes (U), and downstairs for 1.5 minutes (D), alternated by recovery phases. The results were compared with performances measured in a control population of healthy subjects and in two paced patient populations (one equipped with a Dash Intermedics VVIR pacemaker and the other equipped with a Sensolog III Pacesetter/St. Jude VVIR pacemaker). Sex distribution and mean age between paced patients and control subjects were statistically comparable. The mean heartrate achieved by all paced patients at each time sample was compared with the normograms, assigning acceleration (slope) and rate (rate) scores for exercise and recovery phases. Scores ranged from -10 (hypochronotropic) to +10 (hyperchronotropic). Zero represents exact concordance with the responses of healthy individuals, and values between -2.5 and +2.5 were considered statistically similar to normal. During W, although the overall performances of the Dash, Sensolog, and Opus G did not statistically differ from healthy controls, the scores obtained by the Opus G were significantly closer to controls than those of the two other pacemakers (P = 0.02). For U, the three sensors were hypochronotropic (P = 0.03), though the Opus G was associated with a heart rate response closer to that of healthy controls (P = 0.04). D provided similar mean heart rate scores for the Opus G and the Dash compared with healthy controls, in contrast with the hyperchronotropic behavior of the Sensolog (P = 0.02). Opus G revealed a physiological modulation of the heart rate for W and D tests with a slightly hypochronotropic behavior during U. The Opus G autocalibration function provided daily life performances closer to those of healthy controls than two other pacemakers equipped with a body activity sensor that were manually optimized.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Performance of a Rate Responsive Accelerometer‐Based Pacemaker with Autocalibration During Standardized Exercise and Recovery
Date Crossref
01/06/2002
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Hôpital Cardiologique du Haut-Lévêque pays non établi dans la notice
    Établissement de santé
  • Cardiac Pacing and Clinical Electrophysiology Department pays non établi dans la notice
    Établissement de santé

Hôpital Cardiologique du Haut-Lévêque et Cardiac Pacing and Clinical Electrophysiology Department.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

ECG Monitoring and AnalysisCardiovascular and exercise physiologyHeart Rate Variability and Autonomic Control

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.