A Critical Evaluation of Simple Methods for the Estimation of Free Testosterone in Serum

3751Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : be. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The free and nonspecifically bound plasma hormone levels generally reflect the clinical situation more accurately than total plasma hormone levels. Hence, it is important to have reliable indexes of these fractions. The apparent free testosterone (T) concentration obtained by equilibrium dialysis (AFTC) as well as the fraction of serum T not precipitated by 50% ammonium sulfate concentration (non-SHBG-T; SHBG, sex hormone-binding globulin), often referred to as bioavailable T, appear to represent reliable indexes of biologically readily available T, but are not well suited for clinical routine, being too time consuming. Several other parameters have been used without complete validation, however: direct immunoassay of free T with a labeled T analog (aFT), calculation of free T (FT) from total T and immunoassayed SHBG concentrations (iSHBG), and the free androgen index (FAI = the ratio 100T/iSHBG). In the view of substantial discrepancies in the literature concerning the free or bioavailable T levels, we compared AFTC, FT, aFT, FAI, and non-SHBG-T levels in a large number of sera with SHBG capacities varying from low, as in hirsute women, to extremely high as in hyperthyroidism. All these indexes of bioavailable T correlated significantly with the AFTC concentration; AFTC and FT values were almost identical under all conditions studied, except during pregnancy. Values for aFT, however, were only a fraction of either AFTC or FT, the fraction varying as a function of SHBG levels. Also, the FAI/AFTC ratio varied as a function of the SHBG levels, and hence, neither aFT nor FAI is a reliable index of bioavailable T. The FT value, obtained by calculation from T and SHBG as determined by immunoassay, appears to be a rapid, simple, and reliable index ofbioavailable T, comparable to AFTC and suitable for clinical routine, except in pregnancy. During pregnancy, estradiol occupies a substantial part of SHBG-binding sites, so that SHBG as determined by immunoassay overestimates the actual binding capacity, which in pregnancy sera results in calculated FT values that are lower than AFTC. The nonspecifically bound T, calculated from FT, correlated highly significantly with and was almost identical to the values of non-SHBG-T obtained by ammonium sulfate precipitation, testifying to the clinical value of FT calculated from iSHBG.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A Critical Evaluation of Simple Methods for the Estimation of Free Testosterone in Serum
Date Crossref
01/10/1999
Éditeur
The Endocrine Society
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Ghent University Hospital pays non établi dans la notice
    Établissement de santé
  • University Hospital Ghent Laboratory for Hormonology and Department of Endocrinology pays non établi dans la notice
    Université ou école supérieure

Ghent University Hospital et Laboratory for Hormonology and Department of Endocrinology — University Hospital Ghent.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hormonal and reproductive studiesOvarian function and disordersSexual Differentiation and Disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.