The Challenges of Quantitative Measurement of Lung Deposition Using 99m Tc-DTPA from Delivery Systems with Very Different Delivery Times

28Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : ca, de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

In quantifying aerosol delivery, the drug is often mixed with a radiolabel such as (99m)Tc-DTPA whose deposition is used as a proxy for the drug. (99m)Tc-DTPA deposited in the lung is cleared by a combination of absorption into the pulmonary circulation and mucociliary clearance. If administration is not instantaneous, the image will not include that clearance during administration, a problem raised if comparing devices with different administration times. However, if rates of clearance are measured, it will be possible to "correct" the initial image for the clearance that occurred during administration and before counting. Five adult males inhaled a 5-mL solution containing (99m)Tc-DTPA from a breath enhanced jet nebulizer (LC Plus)over the course of 10 min and a 1.25-mL solution from a vibrating membrane device (eFlow), which was delivered in 2.5 min. Quality assurance was the radioactivity count balance (RCB) defined as the difference in the total radioactivity pre-nebulization less post, divided by pre, and expressed as a percentage. Attenuation calculations used a (57)Co flood source (Macey and Marshall). The "correction" for the clearance of (99m)Tc-DTPA was 0.91 +/- 0.04 (mean +/- SD) for the LC Plus) and 0.96 +/- 0.02 for the eFlow). RCB was -0.6 +/- 3.5% for the LC Plus and -4.7 +/- 6.4% for the eFlow, implying acceptable accuracy. For the LC Plus, lung deposition was 15.9(13.4, 18.4)% (mean and 95% CI) of the charge dose, and for the eFlow it was 32.0(29.0, 35.0)%. This technique gave an acceptable level of accuracy for quantitative planar imaging and allowed the comparison of delivery from devices with very different rates of delivery.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
The Challenges of Quantitative Measurement of Lung Deposition Using <sup>99m</sup> Tc-DTPA from Delivery Systems with Very Different Delivery Times
Date Crossref
01/09/2007
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Inhalation and Respiratory Drug DeliveryCystic Fibrosis Research AdvancesAsthma and respiratory diseases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.