Aller au contenu principal
2005 article

Rapid Progression of Discrete Type A Intramural Hematoma: Prevention of a “Procedure-Related” Complication by Intraoperative Transesophageal Echocardiography

3Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To report a case illustrating the utility of transesophageal echocardiography (TEE) before planned stent-graft placement for chronic type B aortic dissection. CASE REPORT: A 64-year-old man with acute aortic syndrome and an 8-year-old interposition graft in the distal aortic arch for acute type B dissection was referred for dissection of the descending thoracic aorta down to the aortic bifurcation; the false lumen was dilated to 65 mm and was partially thrombosed. The ascending aorta showed discrete, eccentric, 4-mm wall thickening that was not considered clinically significant. Stent-graft closure of the entry tear in the proximal descending thoracic aorta was elected. However, as the endovascular procedure was about to commence, TEE showed striking eccentric thickening of the aortic wall of up to 18 mm. The endovascular procedure was stopped, as it was decided to urgently replace the ascending aorta. The next day, the patient underwent successful ascending aortic replacement and simultaneous antegrade stent-graft implantation over the descending thoracic aortic entry tear via the open aortic arch. The postoperative course was uncomplicated, and the patient was discharged 19 days after surgery. He remains well at 6 months after the procedure. CONCLUSIONS: Our case demonstrates that dissection of the ascending aorta may occur not only due to endograft-induced intimal injury, but may also occur due to underlying but undiagnosed or underestimated disease of the ascending aorta or arch. Besides procedural guidance, intraoperative TEE is a useful tool to detect such disease to avoid subsequent "procedure-related" complications.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
<b>Rapid Progression of Discrete Type A Intramural Hematoma:</b> Prevention of a “Procedure-Related” Complication by Intraoperative Transesophageal Echocardiography
Date Crossref
01/04/2005
Éditeur
International Society of Endovascular Specialists
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Aortic Disease and Treatment ApproachesAortic Thrombus and EmbolismAortic aneurysm repair treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.