Real-time three-dimensional echocardiography: technological gadget or clinical tool?
Rattachement africain : it, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The complex anatomy of cardiac structures requires three-dimensional spatial orientation of images for a better understanding of structure and function, thereby improving image interpretation. Real-time three-dimensional echocardiography is a recently developed technique based on the design of an ultrasound transducer with a matrix array that rapidly acquires image data in a pyramidal volume. The simultaneous display of multiple tomographic images allows three-dimensional perspective and the anatomically correct examination of any structure within the volumetric image. As a consequence, it is less operator-dependent and hence more reproducible. Dedicated software systems and technologies are based on high-performance computers designed for graphic handling of three-dimensional images by providing possibilities beyond those obtainable with echocardiography. This methodology allows simultaneous display of multiple superimposed planes in an interactive manner as well as a quantitative assessment of cardiac volumes and ventricular mass in a three-dimensional format without a pre-established assumption of cardiac chamber geometry. In addition, myocardial contraction and/or perfusion abnormalities are clearly identified. Finally, real-time three-dimensional colour Doppler flow mapping enables complete visualisation of the regurgitant jet and new ways of assessing regurgitant lesion severity. Thus, this technique expands the abilities of non-invasive cardiology and may open new doors for the evaluation of cardiac diseases. In this article, current and future clinical applications of real-time three-dimensional echocardiography are reviewed.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Real-time three-dimensional echocardiography: technological gadget or clinical tool?
- Date Crossref
- 01/03/2007
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.