Comparison of silver-impregnated with standard multi-lumen central venous catheters in critically ill patients*

81Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: To evaluate a new silver-impregnated multi-lumen central venous catheter for reducing catheter-related colonization in intensive care patients. DESIGN: Multicenter, prospective, randomized, controlled clinical study. SETTING: Ten adult intensive care units (multidisciplinary, medical and surgical, university and nonuniversity hospitals) in eight institutions. PATIENTS: A total of 577 patients who required 617 multi-lumen central venous catheters between November 2002 and April 2004 were studied. INTERVENTIONS: Intensive care adult patients requiring multi-lumen central venous catheters expected to remain in place for >or=3 days were randomly assigned to undergo insertion of silver-impregnated catheters (silver group) or standard catheters (standard group). Catheter colonization was defined as the growth of >or=1,000 colony-forming units in culture of the intravascular tip of the catheter by the vortexing method. Diagnosis of catheter-related infection was performed by an independent and blinded expert committee. RESULTS: A total of 320 catheters were studied in the silver group and 297 in the standard group. Characteristics of the patients, insertion site, duration of catheterization (median, 11 vs. 10 days), and other risk factors for infection were similar in the two groups. Colonization of the catheter occurred in 47 (14.7%) vs. 36 (12.1%) catheters in the silver and the standard groups (p = .35), for an incidence of 11.2 and 9.4 per 1,000 catheter days, respectively. Catheter-related bloodstream infection was recorded in eight (2.5%) vs. eight (2.7%) catheters in the silver and the standard groups (p = .88), for an incidence of 1.9 and 2.1 per 1,000 catheter days, respectively. CONCLUSION: The use of silver-impregnated multi-lumen catheters in adult intensive care patients is not associated with a lower rate of colonization than the use of standard multi-lumen catheters.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of silver-impregnated with standard multi-lumen central venous catheters in critically ill patients*
Date Crossref
01/04/2007
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Central Venous Catheters and HemodialysisAcute Kidney Injury ResearchNosocomial Infections in ICU

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.