False-High Blood Salicylate Levels in Neonates With Hyperbilirubinemia
Rattachement africain : il. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Drug assays may yield false-positive results caused by cross-reacting compounds. After finding a serum salicylate concentration of 81 microg/mL by using Trinder's colorimetric method, in a comatose child admitted to the authors' pediatric intensive care unit, in the absence of reported salicylate intake, the authors aimed to compare this situation with the phenomenon involving endogenous digoxin-like substances, which cross-react with the routine assay of digoxin. None of the participants in the study had been exposed to salicylate. Salicylate concentration was measured in all patients using Trinder's colorimetric method and in the second stage of the study also by AxSYM salicylate assay. Salicylate concentration using Trinder's method was 18 +/- 25 (4-81) microg/mL among nine seriously ill children in the pediatric intensive care unit, of whom two children with extensive burns had salicylate levels of 30 and 81 microg/mL, respectively. Salicylate concentrations were 107 +/- 24 (45-143) microg/mL and 60 +/- 25 (28-92) microg/mL, among 18 premature newborns and 18 term newborns, with hyperbilirubinemia, respectively. In the second stage, which involved 22 jaundiced term newborns and cord blood from 21 pregnant women, Trinder's method yielded elevated salicylate blood levels among the hyperbilirubinemic infants: 82 +/- 5 (73-89) microg/mL; however, the AxSYM assay yielded significantly lower blood levels: 2.5 +/- 3.4 (0-10.9) microg/mL (P < 0.0001). Among the pregnant women, salicylate cord blood levels were found to be low-within the limit error of the assay with both assay methods. In conclusion, when salicylate intoxication is suspected, particularly during the neonatal period, it is advisable to measure salicylate levels by immunoassay technology.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- False-High Blood Salicylate Levels in Neonates With Hyperbilirubinemia
- Date Crossref
- 01/12/2000
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Assaf Harofeh Medical Center Department of Pediatrics pays non établi dans la noticeÉtablissement de santé
-
Meir Medical Center pays non établi dans la noticeÉtablissement de santé
-
Sackler School of Medicine Sapir Medical Center pays non établi dans la noticeUniversité ou école supérieure
Department of Pediatrics — Assaf Harofeh Medical Center, Meir Medical Center et Sapir Medical Center — Sackler School of Medicine.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.