Fiber Bragg Gratings Array for Structural Health Monitoring
Rattachement africain : tw. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Experimental and numerical analyses have been carried out to demonstrate the feasibility and evaluate the limitation of using fiber Bragg gratings for impact source location on a cold-rolled aluminum plate. Within the area enveloped by a four-FBG-array, source location is reasonably accurate. Beyond that area, prediction error may not be acceptable. Numerical simulations show that such error may be attributed to the limitation of equipment resolution on the one hand, and angular insensitivity of the FBG on the other hand. Based on the results, it is reasoned that prediction accuracy can be improved by employing stronger light source, steeper filter response, and orthogonal rosettes instead of single axis FBGs.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Fiber Bragg Gratings Array for Structural Health Monitoring
- Date Crossref
- 26/04/2010
- Éditeur
- Informa UK Limited
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
National Taiwan University Department of Mechanical Engineering pays non établi dans la noticeUniversité ou école supérieure
Department of Mechanical Engineering — National Taiwan University.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.