Standardized method for the Holmen pellet tester (NHP100) as a tool for evaluating the physical quality of fish feed
Résumé fourni par la source
The fish feed production industry requires reliable methods measuring the physical quality of feed before it is being released to the customer. The Holmen pellet tester (NHP 100) could be adapted for this purpose, but the special characteristics of fish feed require particular care during testing. The aim of the study was to determine the standardized conditions for using the Holmen tester as a tool measuring the durability of fish feed. Screening tests were performed on commercial fish feed samples to assess the effects of temperature, pressure and cleaning the instrument between runs. The operating pressure was found to be the most important factor that can influence the results. The temperature of the operating air can also alter the results; increased temperatures can cause oil to melt and leak from the pellets. Cleaning the instrument between analyses can also affect the results. This study shows that when these factors are maintained at a standardized level, the Holmen pellet tester is a valuable tool for assessing the physical quality of fish feed giving additional information on the quality of feed pellets compared to other durability tests like DORIS.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Standardized method for the Holmen pellet tester (NHP100) as a tool for evaluating the physical quality of fish feed
- Date Crossref
- 06/11/2014
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.