Aller au contenu principal
Accès ouvert déclaré 2012 article

Comparison of diagnostic performance of different imaging modalities for TAVI-patients

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

In contrast to surgical aortic valve replacement pre procedural assessment of aortic, aortic annulus diameter and prosthesis size is essential for successful percutaneous interventional valve therapy. Among different imaging modalities multislice-computed tomography (MSCT) and transesophageal echocardiography (TEE)are routinely used for patient screening. We sought to evaluate the diagnostic performance of cardiac magnetic resonance tomography (CMR) in this setting, and the difference in diameter measurements between all 3 imaging modalities. 30 patients (mean age 80±8 years, 19 male) were underwent TEE (Philips iE33, Andover, USA), MSCT (64-slice Siemens Somatom, Forchheim, Germany), and CMR (Philips Achieva, Best, Netherlands) studies to assess enddiastolic diameters of aortic annulus, aortic bulbus and ascending aorta. In addition, minimal aortic valve area was assessed by TEE and CMR. CT data were retrospectively triggered and reconstruction was set to 60-75% of the cardiac phase. CMR-studies were prospectively triggered using a free breathing navigator for acquisition of a full 3D volume data set (cardiac phase 50-80%). Subsequent image analysis for MSCT and CMR was performed using the vendor specific dedicated 3D analysis tools. TEE measurements were performed on 2D images of 3-chamber views. Aortic annulus diameter was 24.2±2.8mm for MSCT, 23.36±2.4mm for CMR and 22.6±2.01mm for TEE (p<0.01). Aortic bulbus was measured at 33.71±3.6mm on MSCT, 32.75±2.4mm on CMR and 30.5±2.01mm on TEE images (p<0.01). Ascending aortic diameter was 30.63±5.04mm on MSCT, 28.43±4.11mm on CMR, and 28.5±4.08mm on TEE (p<0.01). Differences between measurements and imaging modalities were assessed by Bland Altman statistics. Mean SD for 1) aortic annulus measurements was 0.8±4.6mm for TEE versus CMR and 1.1±3.7 mm for MSCT versus CMR, 2) aortic bulbus diameters 2.2±2.7 mm for TEE versus CMR and 1.0±3.7 mm for MSCT versus CMR, and 3) ascending aorta 0.9±3.1mm for TEE versus CMR and 2.2±3.5 mm for MSCT versus CMR. The minimal aortic valve area showed good agreement between CMR and TEE, standard deviation 0.04±0.41 sqcm. Aortic diameter measurements based on MSCT images were significantly higher compared to CMR and TEE. The lowest diameters were consistently measured on TEE. Our findings may have a relevant clinical impact for decision making in pre procedural TAVI planning and work flow regarding size and type of aortic valve prosthesis.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparison of diagnostic performance of different imaging modalities for TAVI-patients
Date Crossref
01/02/2012
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Heinrich Heine University Düsseldorf Cardiology pays non établi dans la notice
    Université ou école supérieure

Cardiology — Heinrich Heine University Düsseldorf.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCardiac Imaging and DiagnosticsAortic Disease and Treatment Approaches

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.