The effect of microrough surface treatment on miniscrews used as orthodontic anchors

37Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : tw. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: The aim of this study was to investigate the effects of two different microrough surface treatments on miniscrews with loading over different time periods in vivo. MATERIAL AND METHODS: Twenty-four New Zealand white rabbits were selected. One hundred and forty-four miniscrews with a machined (MA), sandblasted and acid-etched (SLA) or sandblasted and alkaline-etched (SL/NaOH) surface were implanted into the tibia of the rabbits. Then, orthodontic forces with Ni-Ti coils were applied immediately to two of the three miniscrews in each tibia, with the center one serving as the control. After 2, 4, 8 and 12 weeks, the rabbits were sacrificed. The removal torque value (RTV) was tested and bone-to-implant contact (BIC) was examined. RESULTS: In most groups, there were no differences between the RTV in the unloaded and loaded conditions at different time periods. In the loaded condition, the RTV of the SLA groups increased significantly after 4 weeks of healing. The RTV in the SL/NaOH groups increased after 8 weeks, and reached a significant difference with the SLA groups after 12 weeks. After 12 weeks, the BIC in the SLA and SL/NaOH groups was higher than in the MA groups. A regression test revealed a moderate correlation between the BIC and the RTV. CONCLUSIONS: There were no differences between the loaded and unloaded conditions in most groups. The RTV and BIC increased with time. In the loaded condition, the RTV of the SLA surface increased earlier, at 4 weeks, while the SL/NAOH group showed the highest RTV after 8 weeks.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The effect of microrough surface treatment on miniscrews used as orthodontic anchors
Date Crossref
08/09/2009
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Orthodontics and Dentofacial OrthopedicsDental materials and restorationsFacial Trauma and Fracture Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.