Aller au contenu principal
2008 article

Effect of intracranial pressure on the diameter of the optic nerve sheath

123Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECT: The subarachnoid space around the optic nerve in the orbit can be visualized using T2-weighted MR imaging with the fat-saturation pulse sequence. The optic nerve sheath (ONS) diameter can be estimated by measuring the outer diameter of the subarachnoid space. Dilated ONS is associated with idiopathic intracranial hypertension and hydrocephalus, and is believed to reflect increased intracranial pressure (ICP). The relationship between dilated ONS and ICP is unclear because of the difficulty in obtaining noninvasive measurements of ICP. The authors investigated the relationship between subdural pressure measured at the time of surgery and ONS diameter measured on MR images in patients with chronic subdural fluid collection. METHODS: Twelve patients underwent bur-hole craniostomy with continuous drainage for chronic subdural hematoma or hygroma in 2006. Orbital thin-slice fat-saturated MR images were obtained before and after surgery, and the ONS diameters were measured just behind the optic globe. Subdural pressure was measured using a manometer before opening of the dura mater. RESULTS: A significant correlation was found between the ONS diameter and the subdural pressure (correlation coefficient 0.879, p = 0.0036). The ONS diameter before surgery (6.1 +/- 0.7 mm) was significantly reduced after surgery (4.8 +/- 0.9 mm, p = 0.003; measurements are expressed as the mean +/- standard deviation). CONCLUSIONS: Increased ONS diameter measured on coronal orbital thin-slice fat-saturated T2-weighted MR images is a strong indicator of increased ICP, and helps to differentiate between passive subdural fluid collection due to brain atrophy and subdural hygroma with increased ICP.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Effect of intracranial pressure on the diameter of the optic nerve sheath
Date Crossref
01/08/2008
Éditeur
Journal of Neurosurgery Publishing Group (JNSPG)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cerebral Venous Sinus ThrombosisTraumatic Brain Injury and Neurovascular DisturbancesHead and Neck Surgical Oncology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.