Somatosensory Evoked Potential Monitoring during Positioning of the Patient for Posterior Fossa Surgery in the Semisitting Position
Rattachement africain : de, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: Midcervical flexion myelopathy is a rare but well-known complication of posterior fossa surgery. To reduce the risk, we routinely used somatosensory evoked potential (SSEP) monitoring during positioning of the patient. METHODS: Fifty-five consecutive patients were operated on for posterior fossa lesions in the semisitting position via a median (5 patients) or a lateral (50 patients) suboccipital approach. During positioning, monitoring of SSEPs by stimulation of the tibial nerve (T-SSEP) as well as by stimulation of the median nerve (M-SSEP) was established. In the case of pronounced SSEP changes, the head was repositioned. Surgery was started after SSEP recordings were unchanged as compared to the baseline investigation. RESULTS: Effective monitoring was possible in all cases. Whereas M-SSEP recordings showed no changes while placing patients in the sitting position, T-SSEP recordings were altered in 14 cases (25%). In cases using the midline approach, SSEP changes were never so pronounced to require repositioning of the head. Head flexion and rotation resulted in significant changes of T-SSEP recordings in eight patients (14.5%), requiring repositioning. In two cases, an amplitude loss was noted. In only two of these eight patients were M-SSEP recordings markedly changed. SSEP recordings after repositioning disclosed recovery of spinal cord function. In no patient were clinical signs of myelopathy observed postoperatively. CONCLUSION: We observed a high incidence of pronounced changes of T-SSEP recordings when the patient's head was flexed and rotated for lateral suboccipital craniotomy in the semisitting position. Despite the low specificity monitoring of T-SSEPs during positioning of the patient for posterior fossa surgery, the semisitting position is strongly recommended.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Somatosensory Evoked Potential Monitoring during Positioning of the Patient for Posterior Fossa Surgery in the Semisitting Position
- Date Crossref
- 01/07/1998
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.