SU-E-CAMPUS-J-06: Development of a Tumor Blood Flow Measurement System for Proton Therapy Patients

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: To develop a tumor blood flow rate measurement system utilizing positron emission after proton therapy for potential evaluation of the efficacy of radiotherapy, concurrent chemotherapy and/or antiangiogenesis therapy of proton therapy patients. Method: Daily proton treatment generates positron emission nuclei, i.e., 15O, 13N and 11C inside the treated volume of patients. In-room measurement of activities of 15O as a function of time right after proton treatment can directly measure tumor blood flow rate due to the biological washout characteristics. A pair of NaI2 detectors and coincidence detection electronics were obtained. The NaI2 detectors were mounted on a modified C-arm for good axial alignment and flexible isocentric rotation. The detector energy spectrum was calibrated using 60Co, 137Cs and 22Na sources. The energy window was set for 511 keV peaks. Current system is not optimized for collimation and shielding. The system performance was evaluated using 18F-FDG. Proton irradiated water and/or ice were also measured for positron emission activity and the acquired data were analyzed. Detector shielding and collimation is under construction. IRB approval for proton patient blood flow rate measurement was obtained for evaluation of their tumor blood flow rates and changes over treatment course. Results: The C-arm based detector platform demonstrated precise alignment and great flexibility for different treatment sites. The 18F-FDG decay measurement using the system showed the measured half life is within 16s of the theoretical value. Activity measurement of proton irradiated water and ice showed about 10s half life difference between the measured and theoretical value. This was potentially due to the activation inside the water/ice container and lack of detector collimation and shielding. Conclusions: A non-invasive in-room tumor blood flow rate measurement system for proton therapy patients is under development. The preliminary data is reported. American Cancer Society Chris DiMarco Institutional Research Grant

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
SU-E-CAMPUS-J-06: Development of a Tumor Blood Flow Measurement System for Proton Therapy Patients
Date Crossref
01/06/2013
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Florida pays non établi dans la notice
    Université ou école supérieure

University of Florida.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Therapy and DosimetryAdvanced Radiotherapy TechniquesNuclear Physics and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.