Aller au contenu principal
2013 article

Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix

3Citations signalées, ce qui n’est pas une note de qualité
9Institutions déclarées
8Pays d’affiliation déclarés

Rattachement africain : Afrique du Sud, ar, Égypte, Kenya, lt, my, Tunisie, vn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

From within AFRIMETS, the Regional Metrology Organization (RMO) for Africa, the RMO Key Comparison AFRIMETS.QM-K27 was coordinated by the National Metrology Institute of South Africa (NMISA) in 2011. Ten Metrology Institutes participated, comprising three AFRIMETS, two APMP, four EURAMET and one SIM participant. Participants were required to determine the forensic level concentration of two aqueous ethanol solutions that were gravimetrically prepared by the NMISA. Concentrations were expected to lie in the range of 0.1 mg/g to 5.0 mg/g. The accurate determination of ethanol content in aqueous medium is critical for regulatory forensic and trade purposes. The CCQM Organic Analysis Working Group has carried out several key comparisons (CCQM-K27 series) on the determination of ethanol in wine and aqueous matrices. Developing NMIs now had the opportunity to link to the earlier CCQM-K27 studies through the AFRIMETS.QM-K27 study. Gas chromatography coupled to flame ionisation or mass spectrometric detection was applied by eight of the participants, while three participants (including NMISA) applied titrimetry for the ethanol assay. The assigned reference value of the aqueous ethanol solutions was used to link AFRIMETS.QM-K27 to the CCQM-K27 key comparison reference value. The assigned reference values for AFRIMETS.QM-K27 Level 1 and Level 2 were (0.3249 ± 0.0021) mg/g (k = 2) and (4.6649 ± 0.0152) mg/g (k = 2), respectively. The reference values were determined using the purity-corrected gravimetric preparation values, while the standard uncertainty incorporated the gravimetric preparation and titrimetric homogeneity uncertainties. From previous CCQM-K27 studies, the expected spread (%CV) of higher order measurements of ethanol in aqueous medium is about 0.85% relative. In this study the CV for Level 1 is about 12% (10% with two outliers removed) and for Level 2 about 4%. Three of the ten laboratories submitted results within 1.5% of the gravimetric reference value for Level 1; four of the ten participating laboratories submitted mean results within 1.5% of the gravimetric reference value for Level 2. Two of the participating laboratories achieved mean results within 1.5% of the gravimetric reference value for both levels. Participants in the AFRIMETS-K27 study would therefore have benefited from a pilot study in which to test their measurement capability prior to participation in the key comparison. Several NMIs, however, will still be able to make new CMC claims based on their performance in this comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix
Date Crossref
01/01/2013
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Spectroscopy and Chemometric AnalysesPesticide Residue Analysis and Safety

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.